  • 32-bit CPU for high-speed number crunching
  • 32-bit floating point & integer math, and multi-loop PID
  • Real time clock and calendar with battery backup
  • Datalogging, up to nearly 1 million analog readings
  • All inputs are transient and overload protected
  • 8 universal inputs: 5V, 20mA, thermistor, pot or contact
  • 3 analog outputs: 0 to 10Vdc
  • 12 optically isolated discrete Inputs:12/24V ac/dc
  • 8 relay discrete outputs w/contact arc suppression
  • 16 Pulse Counters (part of Universal and Discrete Inputs)
  • Networked I/O expansion to thousands of points
  • All electronic “closed case” calibration; no trim pots.
  • Protected serial communications ports:
  • 1 RS-232 only
  • 1 RS-232/RS-485 port
  • Ethernet: 10Base-T 10Mb/second twisted pair
  • Extended industrial temperature operation:
    -40°C to 75°C

The EtherLogic RTU/Controller is an "open architecture" programmable controller with built-in Ethernet and serial communications. It offers 32-bit processing power, network communications and high level software tools that minimize programming time. EtherLogic has "large controller" hardware features and software tools at a cost competitive with ordinary relay replacement "shoebox" controllers.

As an open architecture controller, EtherLogic comes with a full licensed ISaGRAF IEC-61131 package along with support for C and C++, providing a choice of eight different programming languages to minimize retraining and ramp-up time. Mix and match any of these languages to get the job done quickly and reliably.

The open architecture design of EtherLogic extends to its communications capabilities as well. EtherLogic supports industry standard serial communications protocols like Modbus as well as the standard Ethernet and Internet protocols, allowing it to be easily integrated into existing factory Local Area Networks. By not relying on proprietary protocols, EtherLogic is supported by the top HMI software packages like InTouch (Wonderware), FIX (Intellution) and Lookout (National Instruments) with "off-the-shelf" drivers.

The EtherLogic is part of a family of Intelligent RTU's and Controllers which includes the ScadaFlex Plus and ICL-4300. To find out more about features supported by the EtherLogic and other Intelligent RTU's:


EtherLogic Specifications

Back to Top

Universal (Analog/Discrete) Inputs
Quantity 8
Input Types Analog In: 0 to 5Vdc, 0(4) to 20mA, 10K pot, 10K thermistor (Type I & II)

Discrete In: Dry Contact Closure to Common
Discrete In Wetting Current 0.5mA maximum (10K resistor to +5Vdc)
Analog Resolution 10 bits (1 part in 1024)
Analog Non-linearity 0.5 LSB (0.05%)
Discrete Inputs
Quantity 12
Input type Optically isolated with shared isolated common, AC/DC in
ON Input Level 9Vac/Vdc minimum
OFF Input Level 6Vac/Vdc maximum
Maximum input level 50 Vac/Vdc
Discrete Outputs
Quantity 8
Output Type Relay, Form A (normally open) contacts
Output Rating 250Vac/100Vdc max. 10A @ 125 Vac, 5A @ 30 Vdc
Analog Outputs
Quantity 3
Output Type 0 to 10Vdc
Resolution AO1 & AO2: 10 bits (1 part in 1024), AO3: 8 bits (1 part in 256)
Processor: Control & Communications
CPU Intel 386EX, 25MHz
Flash Memory 2MB
RAM Memory 1MB
Real Time Clock Dallas DS1689S (PC compatible)
Processor: Input / Output (I/O)
CPU Atmel ATMEGA163, 6.45MHz
Flash Program Memory 16KB
RAM Memory 1KB
General Specifications
Dimensions 7.0.W x 7.75. L x 2.5. D (178mm W x 197mm L x 64mmD)
Power 24Vac/Vdc +/-15% 3 VA typical, 6 VA maximum
Temperature -40°C to 75°C (-40°F to 167°F)
Humidity 5 to 85% RH (non-condensing)
Communications
Serial Ports 2
Serial Port Interfaces 1st port: RS-232, 9 pin D Male

2nd port: RS-232/RS-485, 5 pin terminal block