MAXIO™

The MAXIO™ distributed I/O system is especially designed to complement ICL Intelligent RTU's and controllers, but can be used in any system requiring Modbus expansion or Modbus remote I/O modules.

Features Selection Guide Specifications DataSheet Technical Manual

Features
Back to Top
  • Modbus RTU communications
  • Bricknet peer-to-peer protocol
  • RS-232 and RS-485 Interfaces
  • Supported by all popular MMI/DCS systems
  • Dipswitch adddressing
  • Fault & transient protected I/O
  • Isolated Field and Comm Wiring
  • Watchdog timer
  • Wide temperature range
  • Hot Swappable for in-service replacement
  • Quick slot screw mounting
  • LED indicators
  • Modular I/O, up to 8,000 points
  • DO Flash functions for alarm annunciation
  • Pulse totalization
  • Multiple I/O Configurations:
    • 24/16 Discrete Inputs/Outputs
    • 16/6 Universal Inputs/Analog Outputs
  • 10 to 36Vdc / 10 to 24Vac Power
  • 3 Year factory warranty
   

Selection Guide

Back to Top

   

MAXIO™ Type

Discrete In

Discrete Out

Analog In

Analog Out

MaxIO D24/16 *

24 16 (Relay) - -

MaxIO U16/6 **

- - 16 6

* "D" stands for Discrete Input and Output
** "U" stands for Universal Input

MAXIO™ distributed I/O modules can significantly reduce system costs by eliminating long runs of field wiring, reducing the size of electrical panels, reducing startup and maintenance time.

MAXIO™ support RS-485 links up to 1 mile over low-cost twisted pair wiring, and RS-232 links for local connections to PC computers and equipment, as well as modem interfaces to data radios, leased telephone lines or fiber optic cable. A single network over any media is expandable to 8,000 I/O points.


Specifications

Back to Top

 
MAXIO™ Discrete Input(61-00xx, 61-02xx)  Datasheet
Quantity/Type of Discrete Input 24
Input Voltage, Nominal 12/24 Vdc/Vac (61-00xx), 120 Vdc/Vac (61-02xx)
Input Operating Range 0 to 60 Vdc/Vac (61-00xx), 0 to 125 Vdc/Vac (61-02xx)
Input Overvoltage Tolerance 140 Vdc/Vac (61-00xx), 190 Vdc/Vac (61-02xx)
Input Resistance, Typical 10,000 ohms (61-00xx), 100,000 ohms (61-02xx)
Input Noise Filtering, AC/DC 20Hz/40Hz (DI 1 thru 4 with filters on)
Counting Frequency, DC (DI 1 thru 4) Greater than 5kHz (DI 1 thru 4 with filters off)
Counting Frequency, AC/DC (all inputs) 10Hz/40Hz (DI 1 thru 4 with filters on)
 
MAXIO™ Discrete Output(61-00xx, 61-02xx)  Datasheet
Quantity of Discrete Outputs 16
Output Type, Configuration Relay (form A)
Output Operating Current/Voltage Range 10A @ 120Vac, 5A @ 30Vdc
Contact Protection Internal RC Snubber
Flash ON/OFF Times/Resolution 0 to 2.55 sec., 10ms increments
 
MAXIO™ Universal Inputs (61-10xx)  Datasheet
Quantity of Analog Inputs 16 (61-10xx)
Universal Input Types Current
20mA ( 0mA to 46mA)
Voltage
5Vdc (0Vdc to 5.625Vdc)
+/-300mV (-300mV to +300mV)
Resistance
65,000 ohms (0 to 65,535 ohms)
Thermocouple
Type J (-240.7 to 1199.0 degrees C)
Type K (-261.2 to 1369.5 degrees C)
Type T (-263.2 to 398.8 degrees C)
Type E (-267.4 to 999.0 degrees C)
Type R (-43.1 to 1759.8 degrees C)
Type S (-41.3 to 1759.1 degrees C)
Type B (-253.4 to 1792.1 degrees C)
Type N (-255.4 to 1296.8 degrees C)
Thermistor
10K Ohm - II (-401 to 173.9 degrees C)
10K Ohm - III (-401 to 188.0 degrees C)
RTD
100 Ohm - 385 (-198.9 to 869.4 degrees C)
100 Ohm - 392 (-200.0 to 629.7 degrees C)
1K Ohm - 385 (-198.9 to 869.4 degrees C)
Discrete Input
TTL Level
Dry Contact
Resolution 16 bits (1 part in 65,535)
Input Overload Tolerance Input voltage limiting starts a 6Vdc
Input current limited to 50mA
Overload / Transient Protection Transorb & Self Resetting Polyfuse
Coversion Rate Approx. 2 samples/sec. per point
Noise Rejection (50/60Hz) -120 dB
 
MAXIO™ Analog Output (61-10xx)  Datasheet
Quantity of Discrete Outputs 6
Output Type, Configuration 0 or 4 to 20mA (0 to 21mA)
Converter Type High-frequency PWM
Resolution 12 bits (1 part in 4096)
Maximum Load Resistance 250 ohms @ 10Vdc loop power
500 ohms @ 15Vdc loop power
750 ohms @ 20Vdc loop power
1000 ohms @ 25Vdc loop power
 
MAXIO™ Communications - All Modules
Serial Ports 1, Isolated RS-232 and RS-485, 1 RS-232 Radio / Modem Diagnostic port
Data Rate 2400 baud to 115K baud
Communications Protocols Modbus RTU / Bricknet (Auto-sensing)
 
MAXIO™ General Specifications - All Modules
Dimensions 7.0” W x 6.0” L x 2.5” D (178mm x 152mm x 64mm)
Power (Input Voltage Range) 8 to 26Vac, 10 to 36Vdc
Sensor Power Supply 7 to 32Vdc, 0.75A maximum
Temperature, operating -40°C to 75°C (-40°F to 167°F)
Temperature, storage -40°C to 100°C (-40°F to 212°F)
Isolation, Field to Logic 2,000 volts
Humidity 5 to 85% RH (non-condensing)
Wiring Terminations Removable Terminal Blocks
#14 to #26 stranded, #12 solid



Download Datasheet:

Back to Top


Download Technical Reference Manual


* PDF format -- requires Adobe Acrobat Reader 4.0 or newer.
* Click below to get it for free.

*