Industrial Control Links offers a wide variety of alarm autodialer,
alarm detection and delivery solutions. Alarm conditions can range
from a simple contact closure to conditions involving many inputs and
logic of arbitrary complexity. Alarm annunciation and delivery can
take many forms: control outputs, voice over telephone or public
address systems, numeric and alphanumeric pager activation, textual
user interface and data communications events. For outstanding flexibility and value, our products offer much more capability than traditional alarm autodialers. To help choose the right solution for your application, see the selection chart below: |
![]()
|
| RTU in a Brick | PC in a Brick | |||
|
Maximum number of alarm conditions
|
18 | 36 | 36 | virtually unlimited |
|
Digital inputs
|
6 | 12 | 12 | up to 64 onboard, virtually unlimited with expansion modules |
|
Analog inputs
|
2 | 8 | 8 | up to 64 onboard, virtually unlimited with expansion modules |
|
Digital outputs
|
4 | 6 | 6 | up to 64 onboard, virtually unlimited with expansion modules |
|
Analog outputs
|
0 | 2 (each AO reduces AI count by 1) | 2 | up to 64 onboard, virtually unlimited with expansion modules |
|
Alarm annunciation / delivery methods
|
local output numeric pager |
local output numeric pager voice over telephone |
local output numeric pager voice over telephone |
local output numeric pager alphanumeric pager voice over telephone (Voice User Interface - VUI) Textual User Interface (TUI) communications (Modbus, BrickNet) |
|
Acknowledge methods
|
local input communications (Modbus) telephone |
local input communications (Modbus) telephone |
local input communications (Modbus) telephone |
local input communications (Modbus, Modbus/TCP, BrickNet) local Textual User Interface (TUI) telephone, with Voice User Interface (VUI) |
|
Alarm logging
|
no | no | no | yes - completely configurable |
|
Alarm Log access methods
|
n/a | n/a | n/a | FTP - TCP/IP
Internet intranet direct connection dialup modem spread spectrum radio |
|
Alarm debounce
|
yes | yes | yes | yes |
|
Alarm hysteresis
|
yes | yes | yes | yes |
|
Local alarm status display
|
no | no | no | yes - via TUI (Textual User Interface) |
|
Local alarm log display
|
no | no | no | yes - via TUI (Textual User Interface) |
|
Complex alarm logic
|
no | no | no | yes - arbitrary complexity |
|
Programmable control logic
|
no | no | no | yes - allows programs of arbitrary complexity using C, ISaGRAF (IEC-61131) or ESP (Easy Setup without Programming) |